Curtain wall safety performance design requirements a recently summarized the main review contents of architectural glass curtain wall and classified them, hoping to provide a little reference for architectural glass curtain wall reviewers and designers of glass curtain wall companies.

Design requirements for safety performance of curtain wall(圖1)

1、 Fire protection design requirements of glass curtain wall

The secondary design of glass curtain wall needs to implement the fire protection requirements in the vertical and horizontal directions of glass curtain wall in the architectural construction drawings and the setting requirements of fire rescue windows.

1. Vertical fire protection requirements of glass curtain wall

(1) Vertical fireproof sealing of glass curtain wall

According to the provisions of article 4.0.3 of technical standard for application of building fire blocking (GB / t51410-2020), the fire blocking structure between layers of glass curtain wall shall be set up with two layers, the thickness of each layer shall not be less than 200mm, and the spacing between the two layers shall not be less than 1.20m. When automatic fire extinguishing system is set, it shall not be less than 0.80M.

(2) When the original building replaces the interlayer solid wall with fireproof glass wall, it shall meet the provisions of article 6.2.5 of the building code. The fire resistance integrity of fireproof glass wall of high-rise building shall not be less than 1.00h, and that of fireproof glass wall of multi-storey building shall not be less than 0.50h, The fire resistance integrity shall be measured according to the test method and judgment standard of non thermal insulation glass inlaid components in the current national standard fire resistance test method of glass inlaid components (GB / T 12513). The height of fireproof glass wall shall not be less than 1.20m, and shall not be less than 0.80M when automatic fire extinguishing system is set.

2. Fire protection requirements for horizontal direction of glass curtain wall

When the transparent glass curtain wall is located within the horizontal distance of 2.0m from the nearest edge on both sides of the firewall or within the horizontal distance of 4.0m from the nearest edge on both sides of the corner in the firewall, it shall meet the provisions of articles 6.1.3 and 6.1.4 of the building code. That is, class B fire windows that can be fixed or closed automatically in case of fire shall be set, and their fire resistance, thermal insulation and fire integrity shall not be less than 1.0h, and their fire resistance shall be measured according to the test method and judgment standard of thermal insulation glass inlaid components in the national standard fire resistance test method of glass inlaid components (GB / T 12513).

3. Setting requirements of fire rescue window

The position and size of the fire rescue window in the secondary design and construction drawing of the glass curtain wall shall be consistent with the original building construction drawing, and the net size of the fire rescue window sash shall not be less than 1.0mx1 0m, it should be noted that its glass should be easy to break.

Design requirements for safety performance of curtain wall(圖2)

2、 Safety protection requirements for free space of glass curtain wall

The secondary design of the glass curtain wall needs to implement the design requirements of the architectural construction drawings on the safety protective glass breast board at the free space and replacing the low windowsill protective window railing with a fixed leaf.

1. The effective clear height of safety protective glass breast boards at the accessible roof, veranda, terrace, open balcony and other adjacent places shall meet the requirements of the original building construction drawings and relevant regulations and standards. The breast board glass shall meet the provisions of article 7.2.5 of technical code for application of building glass JGJ # 113-2015.

2. When the fixed leaf of glass curtain wall is used to replace the window railing, the following requirements shall be implemented:

(1) The horizontal keel of the glass curtain wall shall be 800mm high from the floor. The size, wall thickness and fixing measures between the glass curtain wall keel and the main body of the building shall be indicated. The calculation sheet reviewed and approved by the structure discipline or the test report meeting the anti-collision requirements of the load code shall be provided.

(2) The fixed fan glass shall meet the provisions of article 7.2.5 of technical code for application of building glass JGJ # 113-2015. The minimum requirement is that a layer of glass of insulating glass shall be 6.38 thick laminated glass (note that the structure of the fixed fan shall meet the energy-saving requirements at the same time).

Design requirements for safety performance of curtain wall(圖3)

3、 Design requirements for smoke control and smoke exhaust of glass curtain wall

The secondary design of glass curtain wall needs to implement the smoke control and smoke exhaust requirements of glass curtain wall in architectural construction drawings.

1. Natural ventilation requirements.

For enclosed staircases and smoke proof staircases with natural ventilation, openable external windows with an area of not less than 1.0m2 shall be set at the highest part; When the building height is greater than 10m, openable external windows with a total area of not less than 2.0m2 shall be set every 5 floors on the outer wall of the staircase, and the layout interval shall not be greater than 3 floors; The area of openable external windows in independent front room and fire elevator front room with natural ventilation shall not be less than 2.0m2, and the area of shared front room and shared front room shall not be less than 3.0m2; The refuge floor (room) with natural ventilation shall be equipped with openable external windows in different directions, and its effective area shall not be less than 2% of the ground area of the refuge floor (room), and the area of each direction shall not be less than 2.0m2.

2. Requirements for natural smoke exhaust

Where the ventilation discipline adopts natural smoke exhaust, the effective opening area of the smoke exhaust window within the height range of the smoke storage bin shall meet the requirements of the ventilation discipline, and the effective smoke exhaust area shall be calculated according to article 4.3.5 of the technical standard for building smoke control and smoke exhaust system gb51251-2017. The opening form is detailed in detail (detail I). Note that when the external window is a suspended window, the opening angle of the suspended window shall be indicated in the elevation.

Design requirements for safety performance of curtain wall(圖4)

(excerpt) author: Song Yingfang

Popular videos
Popular products
Look around
主站蜘蛛池模板: 国产色爱av资源综合区| 亚洲精品国产一区黑色丝袜| 永久黄网站色视频免费直播| 激情无码人妻又粗又大中国人| 亚洲三级在线中文字幕| 亚洲国产成人福利精品| 无套内射在线无码播放| 欧美亚洲另类丝袜综合网| 99热成人精品热久久| 少妇扒开粉嫩小泬视频| 欧美综合精品久久久久成人影院 | 伊人久久大香线蕉午夜| 天堂亚洲国产中文在线| 欧美精品无码一区二区三区| 欧美牲交40_50a欧美牲交aⅴ| 久久精品人人做人人爱爱漫画| 国产又色又爽又黄的在线观看| 国产精品久久这里只有精品| 男插女高潮一区二区| 加勒比无码一区二区三区| 无码av中文一二三区| 国产三级做爰在线播放| 在线观看免费网页欧美成| 免费观看又色又爽又湿的视频| 色偷偷色噜噜狠狠网站久久| 亚洲AV无码乱码在线观看性色| 精品国产自在久久现线拍| 青草久久人人97超碰| 无码精品人妻一区二区三区影院| 强制高潮18xxxxhd日韩| 中文无码不卡人妻在线看| 十八禁视频网站在线观看| 日本精品久久久久中文字幕| 手机国产乱子伦精品视频| 狠狠色成人综合网| 玩弄少妇的肉体k8经典| 在线看午夜福利片国产| 国产成人精品亚洲午夜| 在线亚洲专区高清中文字幕| 精品免费一区二区三区在| 香蕉久久夜色精品国产尤物|